Chromium Flange

CAS #:

Linear Formula:

Cr

MDL Number:

MFCD00010944

EC No.:

231-157-5

ORDER

PRODUCT Product Code ORDER SAFETY DATA TECHNICAL DATA
(2N) 99% Chromium Flanges
CR-M-02-FLN
Pricing > SDS > Data Sheet >
(3N) 99.9% Chromium Flanges
CR-M-03-FLN
Pricing > SDS > Data Sheet >
(4N) 99.99% Chromium Flanges
CR-M-04-FLN
Pricing > SDS > Data Sheet >
(5N) 99.999% Chromium Flanges
CR-M-05-FLN
Pricing > SDS > Data Sheet >

Chromium Flange Properties (Theoretical)

Molecular Weight 52
Appearance Silvery
Melting Point 1857 °C
Boiling Point 2672 °C
Density 7.18 g/cm3
Solubility in H2O N/A
Electrical Resistivity 12.9 microhm-cm @ 0 °C
Electronegativity 1.6 Paulings
Heat of Fusion 3.66 Cal/gm mole
Heat of Vaporization 72.97 K-cal/gm atom at 2672 °C
Poisson's Ratio 0.21
Specific Heat 0.107 Cal/g/K @ 25 °C
Tensile Strength N/A
Thermal Conductivity 0.939 W/cm/K @ 298.2 K
Thermal Expansion (25 °C) 4.9 µm·m-1·K-1
Vickers Hardness 1060 MN m-2
Young's Modulus 279 GPa

Chromium Flange Health & Safety Information

Signal Word Warning
Hazard Statements H400
Hazard Codes N/A
Risk Codes N/A
Safety Statements N/A
RTECS Number GB4200000
Transport Information N/A
WGK Germany 3

View and Print SDS

SAFETY DATA SHEET

Date Accessed: 11/13/2024
Date Revised:01/15/2022

SECTION 1. IDENTIFICATION

Product Name: Chromium Flange

Product Number: All applicable American Elements product codes, e.g. CR-M-02-FLN , CR-M-03-FLN , CR-M-04-FLN , CR-M-05-FLN

CAS #: 7440-47-3

Relevant identified uses of the substance: Scientific research and development

Supplier details:
American Elements
10884 Weyburn Ave.
Los Angeles, CA 90024
Tel: +1 310-208-0551
Fax: +1 310-208-0351

Emergency telephone number:
Domestic, North America: +1 800-424-9300
International: +1 703-527-3887


SECTION 2. HAZARDS IDENTIFICATION

Classification of the substance or mixture
Classification according to Regulation (EC) No 1272/2008
The substance is not classified as hazardous to health or the environment according to the CLP regulation.
Classification according to Directive 67/548/EEC or Directive 1999/45/EC
N/A
Information concerning particular hazards for human and environment:
No data available
Hazards not otherwise classified
No data available
Label elements
Labelling according to Regulation (EC) No 1272/2008
N/A
Hazard pictograms
N/A
Signal word
N/A
Hazard statements
N/A
WHMIS classification
Not controlled
Classification system
HMIS ratings (scale 0-4)
(Hazardous Materials Identification System)
HEALTH
FIRE
REACTIVITY



Health (acute effects) = 0
Flammability = 0
Physical Hazard = 0
Other hazards
Results of PBT and vPvB assessment
PBT:
N/A
vPvB:
N/A


SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS

Substances
CAS No. / Substance Name:
7440-47-3 Chromium
Identification number(s):
EC number: 231-157-5


SECTION 4. FIRST AID MEASURES

Description of first aid measures
General information No special measures required.
If inhaled: Seek medical treatment in case of complaints.
In case of skin contact: Generally the product does not irritate the skin.
In case of eye contact:
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
If swallowed:
If symptoms persist consult doctor.
Information for doctor
Most important symptoms and effects, both acute and delayed
No data available
Indication of any immediate medical attention and special treatment needed
No data available


SECTION 5. FIREFIGHTING MEASURES

Extinguishing media
Suitable extinguishing agents Special powder for metal fires. Do not use water.
For safety reasons unsuitable extinguishing agents Water
Special hazards arising from the substance or mixture
In case of fire, the following can be released:
Toxic metal oxide fume
Advice for firefighters
Protective equipment: No special measures required.


SECTION 6. ACCIDENTAL RELEASE MEASURES

Personal precautions, protective equipment and emergency procedures Not required.
Environmental precautions:
Do not allow material to be released to the environment without official permits.
Methods and materials for containment and cleanup: Pick up mechanically.
Reference to other sections
See Section 7 for information on safe handling
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.


SECTION 7. HANDLING AND STORAGE

Handling
Precautions for safe handling
Keep container tightly sealed.
Store in cool, dry place in tightly closed containers.
Information about protection against explosions and fires:
No special measures required.
Conditions for safe storage, including any incompatibilities
Requirements to be met by storerooms and receptacles:
No special requirements.
Information about storage in one common storage facility:
No data available
Further information about storage conditions:
Keep container tightly sealed.
Store in cool, dry conditions in well-sealed containers.
Specific end use(s)
No data available


SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION

Additional information about design of technical systems:
No further data; see section 7.
Control parameters
Components with limit values that require monitoring at the workplace:
7440-47-3 Chromium (100.0%)
PEL (USA) Long-term value: 1* 0.5** mg/m3
*metal;**inorganic compds., as Cr
REL (USA) Long-term value: 0.5* mg/m3
*metal+inorg.compds.as Cr;See Pocket Guide App. C
TLV (USA) Long-term value: 0.5 mg/m3
EL (Canada) Short-term value: C 0.1*** ppm
Long-term value: 0.5* 0.01** 0.025*** mg/m3
IARC1,ACGIH A1;*metal, i
norg.**insol.;**water-sol.
EV (Canada) Long-term value: 0.05 mg/m3
Additional information:
No data
Exposure controls
Personal protective equipment
Follow typical protective and hygienic practices for handling chemicals.
Maintain an ergonomically appropriate working environment.
Breathing equipment:
Not required.
Protection of hands:
Not required.
Penetration time of glove material (in minutes)
No data available
Eye protection:
Safety glasses
Body protection:
Protective work clothing.


SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES

Information on basic physical and chemical properties
Appearance:
Form: Solid in various forms
Color: Grey
Odor: Odorless
Odor threshold: No data available.
pH: N/A
Melting point/Melting range: 1907 °C (3465 °F)
Boiling point/Boiling range: 2671 °C (4840 °F)
Sublimation temperature / start: No data available
Flammability (solid, gas)
No data available.
Ignition temperature: No data available
Decomposition temperature: No data available
Autoignition: No data available.
Danger of explosion: No data available.
Explosion limits:
Lower: No data available
Upper: No data available
Vapor pressure at 20 °C (68 °F): 0 hPa
Density at 20 °C (68 °F): 7.19 g/cm3 (60.001 lbs/gal)
Bulk density at 20 °C (68 °F): 3300 kg/m3
Relative density
No data available.
Vapor density
N/A
Evaporation rate
N/A
Solubility in Water (H2O): Insoluble
Partition coefficient (n-octanol/water): No data available.
Viscosity:
Dynamic: N/A
Kinematic: N/A
Other information
No data available


SECTION 10. STABILITY AND REACTIVITY

Reactivity
No information known
Chemical stability
Stable under recommended storage conditions.
Thermal decomposition / conditions to be avoided:
Decomposition will not occur if used and stored according to specifications.
Possibility of hazardous reactions
No dangerous reactions known
Conditions to avoid
No data available
Incompatible materials:
No data available
Hazardous decomposition products:
Toxic metal oxide fume


SECTION 11. TOXICOLOGICAL INFORMATION

Information on toxicological effects
Acute toxicity:
The Registry of Toxic Effects of Chemical Substances (RTECS) contains acute toxicity data for components in this product.
LD/LC50 values that are relevant for classification:
No data
Skin irritation or corrosion:
Generally the product does not irritate the skin.
Eye irritation or corrosion:
May cause irritation
Sensitization:
No sensitizing effects known.
Germ cell mutagenicity:
The Registry of Toxic Effects of Chemical Substances (RTECS) contains mutation data for this substance.
Carcinogenicity:
IARC-3: Not classifiable as to carcinogenicity to humans.
ACGIH A4: Not classifiable as a human carcinogen: Inadequate data on which to classify the agent in terms of its carcinogenicity in humans and/or animals.
(inhalation) EPA-A: human carcinogen: sufficient evidence from epidemiologic studies to support a causal association between exposure and cancer.
(inhalation) EPA-K: Known human carcinogens.
(oral) EPA-D: Not classifiable as to human carcinogenicity: inadequate human and animal
evidence of carcinogenicity or no data are available.
(oral) EPA-CBD: Carginogenic potential cannot be determined.
The Registry of Toxic Effects of Chemical Substances (RTECS) contains tumorigenic and/or carcinogenic and/or neoplastic data for this substance.
Reproductive toxicity:
The Registry of Toxic Effects of Chemical Substances (RTECS) contains reproductive data for this substance.
Specific target organ system toxicity - repeated exposure:
No effects known.
Specific target organ system toxicity - single exposure:
No effects known.
Aspiration hazard:
No effects known.
Subacute to chronic toxicity:
No effects known.
Additional toxicological information:
To the best of our knowledge the acute and chronic toxicity of this substance is not fully known.


SECTION 12. ECOLOGICAL INFORMATION

Toxicity
Aquatic toxicity:
No data available
Persistence and degradability
No data available
Bioaccumulative potential
No data available
Mobility in soil
No data available
Additional ecological information:
Do not allow material to be released to the environment without official permits.
Do not allow undiluted product or large quantities to reach groundwater, water courses, or sewage systems.
Avoid transfer into the environment.
Results of PBT and vPvB assessment
PBT:
N/A
vPvB:
N/A
Other adverse effects
No data available


SECTION 13. DISPOSAL CONSIDERATIONS

Waste treatment methods
Recommendation
Consult official regulations to ensure proper disposal.
Uncleaned packagings:
Recommendation:
Disposal must be made according to official regulations.


SECTION 14. TRANSPORT INFORMATION

UN-Number
DOT, ADN, IMDG, IATA
N/A
UN proper shipping name
DOT, ADN, IMDG, IATA
N/A
Transport hazard class(es)
DOT, ADR, ADN, IMDG, IATA
Class
N/A
Packing group
DOT, IMDG, IATA
N/A
Environmental hazards:
N/A
Special precautions for user
N/A
Transport in bulk according to Annex II of MARPOL73/78 and the IBC Code
N/A
Transport/Additional information:
DOT
Marine Pollutant (DOT):
No


SECTION 15. REGULATORY INFORMATION

Safety, health and environmental regulations/legislation specific for the substance or mixture
National regulations
All components of this product are listed in the U.S. Environmental Protection Agency Toxic Substances Control Act Chemical substance Inventory.
All components of this product are listed on the Canadian Domestic Substances List (DSL).
SARA Section 313 (specific toxic chemical listings)
7440-47-3 Chromium
California Proposition 65
Prop 65 - Chemicals known to cause cancer
Substance is not listed.
Prop 65 - Developmental toxicity
Substance is not listed.
Prop 65 - Developmental toxicity, female
Substance is not listed.
Prop 65 - Developmental toxicity, male
Substance is not listed.
Information about limitation of use:
For use only by technically qualified individuals.
Other regulations, limitations and prohibitive regulations
Substance of Very High Concern (SVHC) according to the REACH Regulations (EC) No. 1907/2006.
Substance is not listed.
The conditions of restrictions according to Article 67 and Annex XVII of the Regulation (EC) No 1907/2006 (REACH) for the manufacturing, placing on the market and use must be observed.
Substance is not listed.
Annex XIV of the REACH Regulations (requiring Authorisation for use)
Substance is not listed.
REACH - Pre-registered substances
Substance is listed.
Chemical safety assessment:
A Chemical Safety Assessment has not been carried out.


SECTION 16. OTHER INFORMATION

Safety Data Sheet according to Regulation (EC) No. 1907/2006 (REACH). The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. American Elements shall not be held liable for any damage resulting from handling or from contact with the above product. See reverse side of invoice or packing slip for additional terms and conditions of sale. COPYRIGHT 1997-2022 AMERICAN ELEMENTS. LICENSED GRANTED TO MAKE UNLIMITED PAPER COPIES FOR INTERNAL USE ONLY.

About Chromium Flange

 Chromium FlangeChromium flange standards include ASA/ANSI/ASME (USA), PN/DIN (European), BS10 (British/Australian), and JIS/KS (Japanese/Korean). Flange temperature and pressure tolerances are dependent on the rating. American Elements specializes in producing high purity uniform shaped Chromium Flanges. American Elements offers custom flanges with annealed or hard tempers and will meet most of the common Milspec or ASTM standards. Chromium flanges are circular with external ridges and varying threaded holes. In addition to standard alloys, American Elements also specializes in corrosion resistant alloys, high temperature applications, and custom shapes and forms, including custom hole drill locations and threading. American Elements also produces Chromium as rod, ingot, powder, pieces, disc, granules, wire, and in compound forms, such as oxide. Flanges are often used to connect pipes or steam cylinders. Most flanges have external ridges with circular holes so screws can provide extra safety and strength.

Chromium Flange Synonyms

N/A

Chemical Identifiers

Linear Formula Cr
MDL Number MFCD00010944
EC No. 231-157-5
Beilstein/Reaxys No. N/A
Pubchem CID 23976
SMILES [Cr]
InchI Identifier InChI=1S/Cr
InchI Key VYZAMTAEIAYCRO-UHFFFAOYSA-N

Packaging Specifications

Typical bulk packaging includes palletized plastic 5 gallon/25 kg. pails, fiber and steel drums to 1 ton super sacks in full container (FCL) or truck load (T/L) quantities. Research and sample quantities and hygroscopic, oxidizing or other air sensitive materials may be packaged under argon or vacuum. Shipping documentation includes a Certificate of Analysis and Safety Data Sheet (SDS). Solutions are packaged in polypropylene, plastic or glass jars up to palletized 440 gallon liquid totes, and 36,000 lb. tanker trucks.

Related Elements

Chromium

See more Chromium products. Chromium (atomic symbol: Cr, atomic number: 24) is a Block D, Group 6, Period 4 element with an atomic weight of 51.9961. Chromium Bohr ModelThe number of electrons in each of Chromium's shells is 2, 8, 13, 1 and its electron configuration is [Ar] 3d5 4s1. Louis Nicolas Vauquelin first discovered chromium in 1797 and first isolated it the following year. The chromium atom has a radius of 128 pm and a Van der Waals radius of 189 pm. In its elemental form, chromium has a lustrous steel-gray appearance. Elemental ChromiumChromium is the hardest metallic element in the periodic table and the only element that exhibits antiferromagnetic ordering at room temperature, above which it transforms into a paramagnetic solid. The most common source of chromium is chromite ore (FeCr2O4). Due to its various colorful compounds, Chromium was named after the Greek word 'chroma.' meaning color.

TODAY'S TOP DISCOVERY!

November 13, 2024
Los Angeles, CA
Each business day American Elements' scientists & engineers post their choice for the most exciting materials science news of the day
CityUHK researchers discover method to reduce energy loss in metal nanostructures by altering their geometrical dimensions

CityUHK researchers discover method to reduce energy loss in metal nanostructures by altering their geometrical dimensions