American Elements specializes in producing Yttrium Chloride in an ultra dry form for use as a compound in semiconductors and other high purity applications. Ultra Dry Yttrium Chloride is generally immediately available in most volumes. High purity, submicron and nanopowder forms may be considered.American Elements produces to many standard grades when applicable, including Mil Spec (military grade); ACS, Reagent and Technical Grade; Food, Agricultural and Pharmaceutical Grade; Optical Grade, USP and EP/BP (European Pharmacopoeia/British Pharmacopoeia)and follows applicable ASTM testing standards.Typical and custom packaging is available. Additional technical, research and safety (MSDS) information is available as is a Reference Calculator for converting relevant units of measurement.
Yttrium is a Block D, Group 3, Period 5 element. The number of electrons in each of Yttrium's shells is 2, 8, 18, 9, 2 and its electronic configuration is [Kr] 4d1 5s2. In its elemental form Yttrium's CAS number is 7440-65-5. The yttrium atom has a radius of 177.6.pm and it's Van der Waals radius is 200.pm. Insoluble compounds of Yttrium are non-toxic, although water soluble compounds are somewhat toxic. Yttrium has the highest thermo-dynamic affinity for oxygen of any element. This characteristic is the basis for many of its applications. Yttrium is not found in nature as a free element and is almost always found combined with the lanthanides in rare earth minerals. While not part of the rare earth series, it resembles the heavy rare earths which are sometimes referred to as the "yttrics" for this reason. Another unique characteristic derives from its ability to form crystals with useful properties. Yttrium is available as metal and compounds with purities from 99% to 99.999% (ACS grade to ultra high purity); metals in the form of foil, sputtering target, and rod, and compounds assubmicron and nanopowder. Some of the many applications of yttrium include in ceramics for crucibles for molten reactive metals, in florescent lighting phosphors, computer displays and automotive fuel consumption sensors.Yttria stabilized zirconium oxide are used in high temperature applications, such as in thermal plasma sprays to protect aerospace high temperature surfaces and as an electrolyte in solid oxide fuel cells. The name Yttrium originated from a Swedish village near Vaxholm called Yttbery where Yttrium was discovered. Crystals of the yttrium-iron-garnet (YIG) variety are essential to microwave communication equipment. The phosphor Eu:Y2O2S creates the red color in televisions. Crystals of the yttrium-aluminum-garnet (YAG) variety are utilized with neodymium in a number of laser applications. Yttria can also increase the strength of metallic alloys. Yttrium was first discovered by Johann Gadolin in 1794. See Yttrium research below.
PACKAGING SPECIFICATIONS FOR BULK & RESEARCH QUANTITIES
Typical bulk packaging includes palletized plastic 5 gallon/25 kg. pails, fiber and steel drums to 1 ton super sacks in full container (FCL) or truck load (T/L) quantities. Research and sample quantities and hygroscopic, oxidizing or other air sensitive materials may be packaged under argon or vacuum. Shipping documentation includes a Certificate of Analysis and Material Safety Data Sheet (MSDS). Solutions are packaged in polypropylene, plastic or glass jars up to palletized 440 gallon liquid totes.
Low-Fluence Q-Switched 1,064-nm Neodymium-Doped Yttrium Aluminum Garnet Laser for the Treatment of Facial Partial Unilateral Lentiginosis in Koreans.
Lee Y, Choi EH, Lee SW.
Dermatol Surg. 2011 Sep 7. doi: 10.1111/j.1524-4725.2011.02147.x. [Epub ahead of print]
PMID:
22093176
[PubMed - as supplied by publisher]
Successful Treatment of Cosmetic Mucosal Tattoos Via Q-Switched Laser.
Kirby W, Chen C, Desai A, Desai T.
Dermatol Surg. 2011 Aug 23. doi: 10.1111/j.1524-4725.2011.02135.x. [Epub ahead of print]
PMID:
22093036
[PubMed - as supplied by publisher]
Letter: successful treatment of multiple miliary osteomas of the face using an erbium-doped yttrium aluminum garnet laser.
Ortiz AE, Ross EV.
Dermatol Surg. 2011 Oct;37(10):1548-50. doi: 10.1111/j.1524-4725.2011.02112.x.
PMID:
22092945
[PubMed - in process]
Commentary on Treatment of Acne Scars in Asian Patients using a 2,790-nm Fractional Yttrium Scandium Gallium Garnet Laser.
Perez M.
Dermatol Surg. 2011 Oct;37(10):1470-2. doi: 10.1111/j.1524-4725.2011.02116.x. No abstract available.
PMID:
22092942
[PubMed - in process]
Fractional Thermoablation Using an Erbium-Doped Yttrium Aluminum Garnet Fractionated Laser for the Treatment of Pulsed Dye Laser-Resistant Port Wine Stain Birthmarks.
Toren KL, Marquart JD.
Dermatol Surg. 2011 Sep 14. doi: 10.1111/j.1524-4725.2011.02160.x. [Epub ahead of print] No abstract available.
PMID:
22092921
[PubMed - as supplied by publisher]
The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acid-etched implants.
Kim JH, Herr Y, Chung JH, Shin SI, Kwon YH.
J Periodontal Implant Sci. 2011 Oct;41(5):234-41. Epub 2011 Oct 31.
PMID:
22087414
[PubMed - in process]
120-W 2-?m THULIUM:YTTRIUM-ALUMINIUM-GARNET VAPOENUCLEATION OF THE PROSTATE: 12-MONTH FOLLOW-UP.
Muir G.
BJU Int. 2011 Nov 15. doi: 10.1111/j.1464-410X.2011.10816.x. [Epub ahead of print] No abstract available.
PMID:
22085314
[PubMed - as supplied by publisher]
120-W 2-µm thulium:yttrium-aluminium-garnet vapoenucleation of the prostate: 12-month follow-up.
Netsch C, Pohlmann L, Herrmann TR, Gross AJ, Bach T.
BJU Int. 2011 Nov 15. doi: 10.1111/j.1464-410X.2011.10767.x. [Epub ahead of print]
PMID:
22085294
[PubMed - as supplied by publisher]
An Unusual Organoyttrium Alkyl Complex Containing a [C(5) HMe(3) (?(3) -CH(2) )-C(5) H(4) N-?](-) Ligand and an Elusive Cyclopentadienide-Based Scandium Tuck-Over Zwitterion Obtained by C?H Bond Activation.
Jian Z, Cui D.
Chemistry. 2011 Nov 14. doi: 10.1002/chem.201102378. [Epub ahead of print]
PMID:
22083978
[PubMed - as supplied by publisher]
Radioembolization versus Standard Care of Hepatic Metastases: Comparative Retrospective Cohort Study of Survival Outcomes and Adverse Events in Salvage Patients.
Bester L, Meteling B, Pocock N, Pavlakis N, Chua TC, Saxena A, Morris DL.
J Vasc Interv Radiol. 2011 Nov 11. [Epub ahead of print]
PMID:
22079516
[PubMed - as supplied by publisher]
Quantitative evaluation of scintillation camera imaging characteristics of isotopes used in liver radioembolization.
Elschot M, Nijsen JF, Dam AJ, de Jong HW.
PLoS One. 2011;6(11):e26174. Epub 2011 Nov 3.
PMID:
22073149
[PubMed - in process]
Lasers or light sources for treating port-wine stains.
Faurschou A, Olesen AB, Leonardi-Bee J, Haedersdal M.
Cochrane Database Syst Rev. 2011 Nov 9;11:CD007152.
PMID:
22071834
[PubMed - in process]
Treating and Downstaging Hepatocellular Carcinoma in the Caudate Lobe with Yttrium-90 Radioembolization.
Ibrahim SM, Kulik L, Baker T, Ryu RK, Mulcahy MF, Abecassis M, Salem R, Lewandowski RJ.
Cardiovasc Intervent Radiol. 2011 Nov 9. [Epub ahead of print]
PMID:
22069121
[PubMed - as supplied by publisher]
catena-Poly[[tetra-kis-(hexa-methyl-phospho-ramide-?O)bis-(nitrato-?O,O')yttrium(III)] [silver(I)-di-?-sulfido-molybdenum(VI)-di-?-sulfido]].
Zhang J.
Acta Crystallogr E Struct Rep Online. 2011 Sep 1;67(Pt 9):m1206-7. Epub 2011 Aug 6.
PMID:
22065643
[PubMed]
Yttrium-90 Time-of-Flight PET/CT Is Superior to Bremsstrahlung SPECT/CT for Postradioembolization Imaging of Microsphere Biodistribution.
Kao YH, Tan EH, Ng CE, Goh SW.
Clin Nucl Med. 2011 Dec;36(12):e186-7.
PMID:
22064104
[PubMed - in process]
End-functionalized Polymerization of 2-Vinylpyridine through Initial C-H Bond Activation of N-Heteroaromatics and Internal Alkynes by Yttrium Ene-diamido Complexes.
Kaneko H, Nagae H, Tsurugi H, Mashima K.
J Am Chem Soc. 2011 Nov 7. [Epub ahead of print]
PMID:
22059504
[PubMed - as supplied by publisher]
Catalytic, Enantioselective Intramolecular Hydroamination of Primary Amines Tethered to Di- and Tri-substituted Alkenes.
Chapurina Y, Ibrahim H, Guillot R, Kolodziej E, Collin J, Trifonov A, Schulz E, Hannedouche J.
J Org Chem. 2011 Nov 7. [Epub ahead of print]
PMID:
22059438
[PubMed - as supplied by publisher]
Size effect of endohedral cluster on fullerene cage: Preparation and structural studies of Y(3)N@C(78)-C(2).
Ma Y, Wang T, Wu J, Feng Y, Xu W, Jiang L, Zheng J, Shu C, Wang C.
Nanoscale. 2011 Nov 7. [Epub ahead of print]
PMID:
22057827
[PubMed - as supplied by publisher]
MDCT Necrosis Quantification in the Assessment of Hepatocellular Carcinoma Response to Yttrium 90 Radioembolization Therapy: Comparison of Two-dimensional and Volumetric Techniques.
Galizia MS, Töre HG, Chalian H, McCarthy R, Salem R, Yaghmai V.
Acad Radiol. 2011 Nov 2. [Epub ahead of print]
PMID:
22054801
[PubMed - as supplied by publisher]
Q-switched laser treatment of amiodarone pigmentation.
Bernstein EF.
J Drugs Dermatol. 2011 Nov 1;10(11):1316-9.
PMID:
22052315
[PubMed - in process]
Information pertaining to particular dangers for man and environment
Not applicable
HMIS ratings (scale 0-4)
Hazardous Materials Identification System
Health (acute effects) = 1
Flammability = 0
Reactivity = 0
4 First aid measures
After inhalation
Supply fresh air. If required, provide artificial respiration. Keep patient warm. Consult doctor if symptoms persist.
Seek immediate medical advice.
After skin contact
Instantly wash with water and soap and rinse thoroughly.
Seek immediate medical advice.
After eye contact
Rinse opened eye for several minutes under running water. Then consult doctor.
After swallowing Seek medical treatment.
5 Fire fighting measures
Suitable extinguishing agents
Use fire fighting measures that suit the environment.
Protective equipment:
Wear self-contained breathing apparatus.
Wear full protective suit.
Measures for environmental protection:
Do not allow material to be released to the environment without proper governmental permits.
Measures for cleaning/collecting: Collect mechanically.
Additional information:
See Section 7 for information on safe handling
See section 8 for information on personal protection equipment.
See Section 13 for information on disposal.
7 Handling and storage
Handling
Information for safe handling:
Keep containers tightly sealed.
Store in cool, dry place in tightly closed containers.
No special precautions necessary if used correctly.
Information about protection against explosions and fires:
The product is not flammable
Storage
Requirements to be met by storerooms and containers:
No special requirements.
Information about storage in one common storage facility: Not required.
Further information about storage conditions:
This product is hygroscopic.
Protect from humidity and water.
Store under dry inert gas.
Store in cool, dry conditions in well sealed containers.
8 Exposure controls and personal protection
Additional information about design of technical systems:
Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.
Components with critical values that require monitoring at the workplace:
Not required.
Additional information: No data
Personal protective equipment
General protective and hygienic measures
The usual precautionary measures should be adhered to in handling the chemicals.
Keep away from foodstuffs, beverages and food.
Instantly remove any soiled and impregnated garments.
Wash hands during breaks and at the end of the work.
Breathing equipment: Use breathing protection with high concentrations.
Protection of hands: Impervious gloves
Eye protection: Safety glasses
Body protection: Protective work clothing.
9 Physical and chemical properties:
General Information
Form: Crystalline aggregates
Colour: White
Smell: Odourless
Value/Range Unit Method
Change in condition
Melting point/Melting range: Not determined
Boiling point/Boiling range: Not determined
Sublimation temperature / start: Not determined
Flash point: Not applicable
Inflammability (solid, gaseous) Product is not inflammable.
Ignition temperature: Not determined
Decomposition temperature: Not determined
Danger of explosion: Product is not explosive.
Critical values for explosion:
Lower: Not determined
Upper: Not determined
Steam pressure: Not determined
Density Not determined
Solubility in / Miscibility with
Water: Soluble
10 Stability and reactivity
Thermal decomposition / conditions to be avoided:
No decomposition if used and stored according to specifications.
Materials to be avoided:
Water/moisture
Oxidizing agents
Acids
Bases
Dangerous reactions: No dangerous reactions known
Dangerous products of decomposition: Hydrogen chloride (HCl)
Metal oxide fume
11 Toxicological information
Acute toxicity:
Primary irritant effect:
on the skin: May cause irritation
on the eye: May cause irritation
Sensitization: No sensitizing effect known.
Additional toxicological information:
To the best of our knowledge the acute and chronic toxicity of this substance is not fully known.
No classification data on carcinogenic properties of this material is available from the EPA, IARC, NTP, OSHA or ACGIH.
12 Ecological information:
General notes:
Do not allow material to be released to the environment without proper governmental permits.
Generally not hazardous for water.
13 Disposal considerations
Product:
Recommendation
Consult state, local or national regulations for proper disposal.
Hand over to disposers of hazardous waste.
Must be specially treated under adherence to official regulations.
Uncleaned packagings:
Recommendation:
Disposal must be made according to official regulations.
14 Transport information
Land transport ADR/RID and GGVS/GGVE (cross-border/domestic)
ADR/RID-GGVS/E Class: None
Maritime transport IMDG/GGVSea:
IMDG/GGVSea Class: None
Air transport ICAO-TI and IATA-DGR:
ICAO/IATA Class: None
Transport/Additional information:
Not dangerous according to the above specifications.
15 Regulatory information
Designation according to EC guidelines:
Observe the normal safety regulations when handling chemicals
National regulations
All components of this product are listed in the U.S. Environmental Protection Agency Toxic Substances Control Act Chemical substance Inventory.
Information about limitation of use:
For use only by technically qualified individuals.
16 Other information:
Employers should use this information only as a supplement to other information gathered by them, and should make independent judgement of suitability of this information to ensure proper use and protect the health and safety of employees. This information is furnished without warranty, and any use of the product not in conformance with this Material Safety Data Sheet, or in combination with any other product or process, is the responsibility of the user.